Elemental analysis - جهاز تحليل العناصر

vario MACRO cube(CHNS)

Type : vario MACRO cube(CHNS)

  • Quantitative sample digestion at up to 1,200 °C, or 1,800 °C
  • Spanning from micro (<1 mg) to macro (800 mg soil)
  • up to 20 mg of organic matter
  • Up to 40 mg C abs, or 15 mg N abs, from ppm to 100%
Rapid OXY cube

Type : Rapid OXY cube

  • From ppm to 100% or 6 mg O absolute
  • Processes controlled and evaluated through a Windows PC.
  • The integrated sample feeder accommodates 120 samples
Trace SN cube

Type : Trace SN cube

  • temperature combustion in the carrier gas at up to 1,150 °C
  • The instrument’s CLD and UV-fluorescence detection methods
  • Detection limits are set at 6 ppb for S and 15 ppb for N
  • injection volume of 20 µl for liquids or 20 ml for gas samples
acquray® Series

Model : acquray® Series

  • UV-/persulfate digestion for an injection volume up to 40 ml
  • determination of NPOC, TOC, TIC and TC in liquids
  • 21 CFR Part 11 functionality available
  • concentration range: From low ppb up to percent carbon for liquids
  • automated acidification module and PC-control through Windows
Vario TOC cube

Model : Vario TOC cube

  • High temperature catalytic oxidation up to 1200 °C
  • CO2-measurement with NDIR for TOC, NPOC, TC, TIC, POC (VOC), DOC. TNb
  • 21 CFR Part 11 functionality available
  • detection range: From low ppb to percent
soli TOC® cube

Model : soli TOC® cube

  • temperature ramping in an oxygenated atmosphere up to 900 °C
  • for TOC, ROC and TIC determination in solids compliant with DIN 19539
  • 21 CFR Part 11 functionality available
  • concentration range: From a few ppm up to 100% or 50 mg carbon and 20 mg (0–15%) nitrogen absolute
UNICUBE

Type : UNICUBE (CN analysis of carbon loads)

  • temperature near 1,200 °C, reaching 1,800 °C during combustion
  • measuring range is 0-100%, or 20 mg S absolute
  • measuring range for carbon is 0-100%, or up to 40 mg absolute
  • concentrations of below 1 ppm or 0.2 µg S can be detected
Rapid N exceed

Type :Rapid N exceed

  • Dumas combustion method for N/Protein acc. to AOAC, DIN/ISO, EN
  • 21 CFR Part 11 functionality available
  • Weighing range: Up to 1 g sample weight (1 g organic matter)
  • Concentration range: from ppm to 100% or 500 mg N abs
Inductor CS cube

Type : Inductor CS cube

  • temperature-combustion in oxygen atmosphere at up to 2000 °C
  • solid samples are weighed into ceramic sample containers (sample mass up to 1 g)
  • concentration range: From a few ppm up to 100 % or 60 mg carbon and 5 mg sulfur absolute
Inductor ONH cube

Type : Inductor ONH cube

  • temperatures up to 3,000°C
  • meaning all kinds of solid samples up to 1g
Inductor EL cube (CHNOS)

Type : Inductor EL cube (CHNOS)

  • automated version with 89 (CS) or 42 (ONH) sample positions
  • manual version with two sample positions
  • analyzed will either combust in oxygen at 2,000°C (CS) or fuse with helium or argon at 3,000°C (ONH)
NEX QC

Type : NEX QC

  • 50kV X-ray tube
  • 4W max power
  • 6 tube filter positions
  • High performance SDD detector
  • Peltier thermo-electric cooling
  • Si PIN Diode Detector
NEX QC+

Type : NEX QC+

  • 50kV X-ray tube
  • 4W max power
  • 6 tube filter positions
  • High performance SDD detector
  • Peltier thermo-electric cooling
  • Si Drift Detector
NEX QC+QuantEZ

Type : NEX QC+QuantEZ

  • 50kV X-ray tube
  • 4W max power
  • 6 tube filter positions
  • High performance SDD detector
  • Peltier thermo-electric cooling
  • Si Drift Detector
  • Standardless FP with user configurable matching libraries
NEX DE

Type : NEX DE

  • 60kV X-ray tube
  • 12W max power
  • 7 tube filter positions
  • 10 mm collimator
  • High performance FAST SDD detector
  • Peltier thermo-electric cooling
  • Fast Si Drift Detector Standardless FP
  • Standardless FP with user configurable matching libraries
NEX DE VS

Type : NEX DE VS

  • 60kV X-ray tube
  • 12W max power
  • 7 tube filter positions
  • 10, 3 and 1mm diameter collimator
  • High performance FAST SDD detector
  • Peltier thermo-electric cooling
  • Fast Si Drift Detector
  • High Resolution Camera
  • Standardless FP
NEX CG

Type : NEX CG

  • X-ray tube with Pd anode
  • 50W max power
  • 50kV max voltage
  • Four standard polarization and secondary targets depending on application, for optimum excitation
  • Optional fifth target for optimal excitation of Na and Mg
  • High performance SDD
  • Peltier electronic cooling
  • High performance SDD Detector
  • Helium purge
  • 16-position sample tray
  • Standardless FP